Excellent Product, Best Service

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsOutdoor Circuit Breaker

Load Control Air Load Break Switch , High Voltage Load Break Switch Short Circuit Protection

Load Control Air Load Break Switch , High Voltage Load Break Switch Short Circuit Protection

Load Control Air Load Break Switch , High Voltage Load Break Switch Short Circuit Protection
Load Control Air Load Break Switch , High Voltage Load Break Switch Short Circuit Protection

Large Image :  Load Control Air Load Break Switch , High Voltage Load Break Switch Short Circuit Protection Get Best Price

Product Details:

Place of Origin: China
Brand Name: Comking
Certification: ISO9001,ISO14001,OHSAS18001
Model Number: CKWZ

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: To be discussed later
Packaging Details: Wooden Packing
Delivery Time: 10-15 work days
Payment Terms: L/C, T/T, Western Union
Detailed Product Description
Rated Voltage: 12kV Rated Current: 630A
Rated Frequency: 50Hz Type: Outdoor
High Light:

outside circuit breaker

,

3 phase breaker

1. Description

CKWZ is a three-phase AC outdoor vacuum circuit breaker maximum up to 24kV rated voltage and 50Hz rated frequency.

 

2. Working Condition

2.1 Ambient air temperature: -45℃~+40℃,daily range of temperature: diurnal variation 25℃

2.2 Relative humidity: daily average data ≤95%, monthly average data ≤90%

2.3 Seismic capacity: ≤magnitude 8, horizontal acceleration ≤ 0.4g, vertical acceleration ≤ 0.2g

2.4 Altitude: ≤1000m

2.5 Pollution classification: IV.

2.6 Wind speed: ≤35m/s

2.7 Applicable in the places without fire, without explosion risk, and without violent vibration

(Exceeding above working condition is available as customized product)

 

3. Technical Data

Description Unit Parameter
Rated voltage kV 12 24
Rated frequency Hz 50 50
Rated current A 630 630
Rated short-time withstand current(4s) kA 20 20
Rated peak withstand current kA 50 50
Rated short-circuit making current(peak) kA 50 50
Rated short-circuit breaking current kA 20 20
Breaking times for rated short-circuit breaking current times 30 30
Mechanical life times 10000 10000
Power frequency withstand voltage(1min) kV 42/48 50/60
Lighting impulse withstand voltage kV 75/85 125/145
Clearance between open contacts mm 9±1 12±1
Withstand voltage for secondary circuit (1 min) V 2000 2000
Opening speed m/s 1.2±0.2 1.4±0.25
Closing speed m/s 0.8±0.2 0.8±0.2
Bounce time for contact’s closing ms ≤2 ≤2
Opening simultaneity for three-phase ms ≤2 ≤2
Loop resistance (without disconnector) μΩ <80 <80

 

4. Standard

---- GB1984-2003

---- GB/T11022-2011

---- GB/T11023-1989

---- GB311.1-1997

---- DL/T593-1996

---- DL/T402-1999

---- GB/T3309-1989

---- DL403-1999

---- IEC62271-100

Contact Details
Zhuhai Comking Electric Co.,Ltd.

Contact Person: Sabrina Yang

Tel: 86 756 8992445

Send your inquiry directly to us