Excellent Product, Best Service

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsSolid Insulated Switchgear

12kV Metal Clad Switchgear , 3 Phase Switchgear Safe Reliable 630A 1250A

12kV Metal Clad Switchgear , 3 Phase Switchgear Safe Reliable 630A 1250A

12kV Metal Clad Switchgear , 3 Phase Switchgear Safe Reliable 630A 1250A
12kV Metal Clad Switchgear , 3 Phase Switchgear Safe Reliable 630A 1250A

Large Image :  12kV Metal Clad Switchgear , 3 Phase Switchgear Safe Reliable 630A 1250A Get Best Price

Product Details:

Place of Origin: China
Brand Name: Comking
Certification: ISO9001,ISO14001,OHSAS18001
Model Number: CKSV

Payment & Shipping Terms:

Minimum Order Quantity: 1set
Price: To be discussed later
Packaging Details: Wooden Packing
Delivery Time: 10-15 work days
Payment Terms: L/C, T/T, Western Union
Detailed Product Description
Rated Voltage: 12kV Rated Frequency: 50Hz
Rated Current: 630A,1250A Insulation: Solid Insulation
High Light:

power distribution equipment

,

electrical switchgear

1. Description
Solid insulated switch is the core of solid insulated ring main switchgear. The switch is designed to integrate vacuum breaker or load switch, disconnector and earthing switch. The structure is compact which includes front side and back side. The front side is operation mechanism, the backside is primary part. Solid insulated switch can be different functional units with switchgear as a module, multiple modules has same structure, same operation.

2. Technical Feature

---- It is the core of solid-insulated switchgear.

---- Including C unit (load break switch), V unit (circuit breaker) & F unit (fuse load break switch).

---- Operating mechanism is at the front side and primary circuit is at the backside. Easily for operation, debug and test.

---- Busbar is at the top side. Easily for assembly if extending more units at left/right side.

---- As an independent component, it can be assembled to be different unit of the switchgear.

3. Working Condition

3.1 Altitude:≤5000m

3.2 Ambient air temperature: -45℃~+70℃

3.3 Relative air humidity: daily average ≤ 95%, monthly average ≤ 90%
3.4 Earthquake degree ≤ 8

3.5 Applicable in the places without fire, without explosion risk, without chemical corrosive and without violent vibration.
(Exceeding above working condition is available as customized product)
 

4. Technical Data

Item

       V  Unit

     C   Unit

    F    Unit

Rated voltage(KV)

   12

   24

   12

    24

   12

   24

Rated current (A)

        800

       630

        125

Rated frequency (Hz)

                            50

Power frequency withstand voltage, phase-to-phase, phase to earth/open contact

                      42/48

  50/60

Lighting impulse withstand voltage (KV)
Phase-to-phase, phase to earth/open contact

                      75/85

 125/145

Rated short-circuit breaking current (KA)

25

 

31.5 (Fuse)

Rated cable-charging breaking current (A)
 

25

10

 

Rated short time withstand current (KA)

25

20

 

Rated short time withstand time (S)

4

4

 

Rated peak withstand current (KA)

63

50

 

Rated short time making current (KA)

63

50

 

Rated breaking transfer current (A)

 

 

3150

Internal arc test AFLR level (KA/S)

25/0.5

Partial discharge (pC)

≤20

Protection level  body/switch

IP4X/IP67

Main circuit resistance (μΩ)

≤ 150

≤ 150

≤ 150

Mechanical life (times) main switch/ disconnector

10000/2000

5000/2000

5000/2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Standard

---- GB/T11022-2011

---- GB1984-2003

---- GB1985-2004

---- GB3804-2004

---- GB3906-2006

---- GB16926-2009

---- IEC62271

---- GB/T1984, GB1985

 

 

Contact Details
Zhuhai Comking Electric Co.,Ltd.

Contact Person: Sabrina Yang

Tel: 86 756 8992445

Send your inquiry directly to us